Before Each Start-Up:
1. Place On/Auto/Off lever to "Off".
2. Turn the regulator knob counter-
clockwise to set the outlet
pressure to zero.
3. Attach hose and accessories.
NOTE: The hose or accessory will
require a quick connect plug if the
air outlet is equipped with a quick
connect socket.
Risk of Bursting.
Too much air
pressure causes a hazardous
risk of bursting. Check the
manufacturer’s maximum pressure
rating for air tools and accessories.
The regulator outlet pressure
must never exceed the maximum
pressure rating.
MAINTENANCE
Customer Responsibilities
Daily
or after
each
use
Before
each
use
Every
100
hours
Yearly
1
1- more frequent in dusty or humid conditions
Check Safety Valve
Drain Tank
Air Filter
To ensure efficient operation and
longer life of the air compressor,
a routine maintenance schedule
Air compressor pump intake
and exhaust valves
Risk of Unsafe
Operation. Unit
cycles automatically when power
is on. When servicing, you may
be exposed to voltage sources,
compressed air, or moving parts.
Before servicing unit unplug or
disconnect electrical supply to
the air compressor, bleed tank
of pressure, and allow the air
compressor to cool.
should be prepared and followed. The
above routine maintenance schedule
is geared to an air compressor in a
normal working environment operating
on a daily basis. If necessary, the
schedule should be modified to
suit the conditions under which
your air compressor is used. The
modifications will depend upon
the hours of operation and the
working environment. Compressors
in an extremely dirty and/or hostile
environment will require a greater
frequency of all maintenance checks.
How to Start:
1. Turn the On/Auto/Off lever to "On/
Auto" and allow tank pressure
to build. Motor will stop when
tank pressure reaches "cut-out"
pressure.
2. Turn regulator knob clockwise to
increase pressure and stop when
desired pressure is reached.
The compressor is ready for use.