Instruction
manual
IMPORTANT
Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.
ESPAÑOL: PÁGINA 29
FRANÇAIS: PAGE 57
To learn more about Porter-Cable
visit our website at:
http://www.porter-cable.com
Copyright © 2004 Porter-Cable Corporation
The Model and Serial No. plate is located on the frame.
Record these numbers in the spaces below and retain for
future reference.
Model No.
Type
Serial No.
Part No. D24938-044-2
Oillube Single-Stage
Portable Compressor
MODEL
CPL6025
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Instruction

InstructionmanualIMPORTANTPlease make certain that the person who isto use this equipment carefully reads andunderstands these instructions beforestar

Seite 2 - IMPORTANT SAFETY INSTRUCTIONS

10- ENGD24938To Assemble WheelsIt will be necessaryto brace or supportone side of the unit when installingthe wheels because thecompressor will have a

Seite 3

11- ENGD249381. Place unit on a level surface. Risk from FlyingObject. Drain tankto release air pressure beforeremoving the dipstick. See "ToDrai

Seite 4 - WARNING: Risk of Bursting

12- ENGD24938IMPORTANT: The outlet being usedmust be installed and grounded inaccordance with all local codes andordinances. 2. Make sure the outlet b

Seite 5 - WARNING: Risk to Breathing

13- ENGD24938Extension CordsUsing extension cords is notrecommended. The use of extensioncords will cause voltage to dropresulting in power loss to th

Seite 6 - WARNING: Risk of Falling

14- ENGD24938Description of OperationBecome familiar with these controlsbefore operating the unit.On/Auto/Off Lever: Turn this switchto "On/Auto&

Seite 7 - SAVE THESE INSTRUCTIONS

Air Compressor Pump (not shown):Compresses air into the air tank.Working air is not available until thecompressor has raised the air tankpressure abov

Seite 8 - ACCESSORIES

16- ENGD249386. Run the compressor for 20minutes. Make sure the drainvalve is open and there isminimal air pressure build-up intank.7. After 20 minute

Seite 9 - ASSEMBLY

17- ENGD24938MAINTENANCECustomer ResponsibilitiesDaily oraftereachuseBeforeeachuse●●●●Every8hoursEvery40hoursEvery100hoursYearlyEvery160hours●●11- mor

Seite 10 - Assemble Rubber Feet

OilNOTE: Use an oil specificallyformulated for use in an aircompressor, such as Porter-CablePAS1 air compressor oil. Oil may befound at the store wher

Seite 11 - To Add Oil To Pump

19- ENGD24938To Replace BeltSerious injury ordamage may occurif parts of the body or loose itemsget caught in moving parts. Neveroperate the unit with

Seite 12 - INSTALLATION

2- ENGD24938SAFETY GUIDELINES - DEFINITIONSIndicates an imminentlyhazardous situationwhich, if not avoided, willresult in deathor serious injury.Indic

Seite 13 - 120/240 Dual Voltage Motor

20- ENGD24938Air Compressor PumpIntake and Exhaust ValvesOnce a year have a Trained ServiceTechnician check the air compressorpump intake and exhaust

Seite 14 - OPERATION

21- ENGD24938SERVICE AND ADJUSTMENTS5. Unscrew the check valve (turncounterclockwise) using a 7/8"open end wrench. Note theorientation for reasse

Seite 15 - How to Use Your Unit

22- ENGD24938d. It is now possible to removeregulator.5. Apply pipe sealant tape to thenipple.6. Assemble the regulator andorient as shown in figure.

Seite 16 - How to Start:

23- ENGD24938STORAGEBefore you store the air compressor,make sure you do the following:1. Review the "Maintenance"section on the preceding p

Seite 17 - MAINTENANCE

24- ENGD24938TROUBLESHOOTINGPerforming repairs may expose voltage sources, movingparts or compressed air sources. Personal injury mayoccur. Prior to a

Seite 18 - To Drain Tank

25- ENGD24938PROBLEMCAUSECORRECTIONCompressor isnot supplyingenough air tooperateaccessories.Prolonged excessive use ofair.Compressor is not largeenou

Seite 19 - Replacement

26- ENGD24938PROBLEMCAUSECORRECTIONMotor will notrun.Fuse blown, circuit breakertripped.1. Check fuse box for blownfuse and replace asnecessary. Reset

Seite 20

27- ENGD24938PROBLEMCAUSECORRECTIONKnocking Noise.Possible defect in safetyvalve.Operate safety valve manuallyby pulling on ring. If valve stillleaks

Seite 21 - SERVICE AND ADJUSTMENTS

28- ENGD24938LIMITED WARRANTYPORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under thiswarranty are free from de

Seite 22 - To Replace Regulator

3- ENGD24938IMPORTANT SAFETY INSTRUCTIONSSave these instructionsImproper operation or maintenance of this product could result in serious injury andpr

Seite 23

4- ENGD24938WARNING: Risk of BurstingAir Tank: The following conditions could lead to a weakening of the tank, and resultin a violent tank explosion a

Seite 24 - TROUBLESHOOTING

5- ENGD24938WARNING: Risk to BreathingWARNING: Risk of Electrical ShockHAZARDHAZARDYour air compressor is powered byelectricity. Like any other electr

Seite 25 - CORRECTION

6- ENGD24938WARNING: Risk of BurnsTouching exposed metal such as thecompressor head or outlet tubes, canresult in serious burns.Never touch any expose

Seite 26

7- ENGD24938Review and understand all instructionsand warnings in this manual.Become familiar with the operation andcontrols of the air compressor.Kee

Seite 27

8- ENGD24938GLOSSARYDUTY CYCLESPECIFICATIONSAccessories for this unit are available at the store the unit was purchased.ACCESSORIESModel No. CPL6025Ho

Seite 28 - LIMITED WARRANTY