OPERATION
KNOW YOUR GENERATOR
Read this General Manual and Safety Rules before operation of your Generator.
Compare the illustration in your parts manual with your generator to familiarize yourself with
the location of various controls and adjustments. Save all manuals for future references.
GENERATOR CAPACITY
IMPORTANT: Exceeding the rated capacity of your generator can result in serious damage
to your generator and connected electrical devices. See the Wattage Calculation section in
this manual to assist you in determining the appliances and tools that can be run with the
wattage capacity of your generator.
CIRCUIT BREAKERS
Each receptacle has a circuit breaker to protect the generator from overloading. If the circuit
breaker trips, unplug all electrical loads from the generator. Let the circuit breaker cool
down. Push circuit breaker button to reset.
LOW OIL PROTECTION
To protect the generator engine from damage, the engine is equipped with a
Low Oil Protection reliability feature.
When the engine has been shut down for refueling or other purposes and the oil
level is low, the Low Oil Protection will prevent the engine from restarting until
sufficient oil has been added. NOTE: The Low Oil Protection mechanism is very
sensitive. You must fill the engine to the full mark on the dipstick to inactivate
this safety device.
IMPORTANT: Low Oil Protection will not automatically shut down the engine if
oil level becomes low while the engine is running. Always check engine oil level
before starting the engine.
BEFORE START UP
This generator has been shipped from the factory without oil in the
crankcase. Operating the unit without oil can damage the engine.
Always check engine oil level before every start. Running engine low
of oil or out of oil could result in serious damage to the engine.
Follow the steps listed below before starting generator:
1. Check engine oil. Refer to the Engine Operator's Manual for
correct grade and quantity of oil.
2. Check fuel level, fill as required. Make sure generator is turned
off and has been allowed time to cool down. Use clean, fresh,
regular unleaded gasoline with a minimum of 87 octane. Do
not mix oil with gasoline.
Never fill fuel tank completely. Fill tank to
1/2" below the bottom of the filler neck to
provide space for fuel expansion. Wipe any fuel spillage from
engine and equipment before starting engine.
Never fill fuel tank indoors. Never fill fuel tank when engine is
running or hot. Do not smoke when filling fuel tank.
Never run engine indoors or in enclosed, poor ventilated areas, en-
gine exhaust contains carbon monoxide, an odorless and deadly
gas.
3. Make sure generator is grounded in accordance with local requirements.
4. All electrical loads MUST be disconnected.