Instruction
manual
IMPORTANT
Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.
Part No. D28453-032-0
ESPAÑOL: PÁGINA 25
FRANÇAIS: PAGE 49
To learn more about Porter-Cable
visit our website at:
http://www.porter-cable.com
Model
H650IS-W
Copyright © 2003 Porter-Cable Corporation
The Model and Serial No. plate is located on the frame.
Record these numbers in the spaces below and retain for
future reference.
Model No.
Type
Serial No.
Generator
Shown with optional portability kit
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - Generator

InstructionmanualIMPORTANTPlease make certain that the person who isto use this equipment carefully reads andunderstands these instructions beforestar

Seite 2 - CONSUMER SAFETY INFORMATION

10- ENGD28453EXTENSION CORDSWhen using an appliance or tool at a considerable distance from the generator, a3-wire extension cord that has a 3-blade g

Seite 3 - IMPORTANT SAFETY INSTRUCTIONS

11- ENGD28453OPERATIONKNOW YOUR GENERATORRead this General Manual and Safety Rules before operation of your Generator.Compare the illustration in your

Seite 4 - HOW TO PREVENT IT

12- ENGD2845312V DC OUTLETIMPORTANT: Allow generator to run at no load for 5 minutes upon each initialstart-up to allow engine to stabilize.IMPORTANT:

Seite 5

13- ENGD28453TO START THE ENGINENever run engine indoors or in enclosed, poor ventilatedareas, engine exhaust contains carbon monoxide, anodorless and

Seite 6

14- ENGD28453CONNECTING ELECTRICAL LOADS1. Let engine run and warm up for five minutes after starting with no electricalload.Connect loads in the foll

Seite 7

15- ENGD28453CONNECTING PROCEDURE FOR RAISING OR SUSPENDINGGENERATORS Failure to properly connect lifting cables, chains, or straps cancause property

Seite 8 - SPECIFICATIONS

16- ENGD28453Note 1: Change oil after first two (2) operating hours and every 50 operatinghours thereafter, more often if operated in extreme dusty or

Seite 9 - ASSEMBLY

17- ENGD28453If you are going to store your generator for more than 30 days, use thefollowing information as a guide to prepare the generator for stor

Seite 10 - DOUBLE THROW TRANSFER SWITCH

18- ENGD28453WATTAGE CALCULATIONSNever exceed the rated capacity of your generator. Serious damage to thegenerator or appliance could result from an o

Seite 11 - OPERATION

19- ENGD28453STARTING WATTAGE REQUIREMENTS1. Some appliances and tools will list on the motor nameplate the startingand running voltage and amperage r

Seite 12 - BEFORE START UP

2- ENGD28453Read Operators Manual. Do not operate equipment until you have readoperators Manual for Safety, Assembly, Operation, and MaintenanceInstru

Seite 13 - TO START THE ENGINE

20- ENGD28453APPLIANCE OR LOAD DEVICE* REFRIGERATOR/ FREEZER 800 SMALL REFRIGERATOR AIR COND.(ROOM) SUMP PUMP 1/2 HP 600 TELEVISION CAUTION !! HOT PLA

Seite 14 - CONNECTING ELECTRICAL LOADS

21- ENGD28453TROUBLESHOOTING GUIDEPROBLEMCAUSECORRECTIONEngine will notstart1. Low on fuel or oil.2. Ignition switch in "Off"position.3. Fau

Seite 15 - GENERATORS

22- ENGD28453LIMITED WARRANTYPORTER-CABLE CORPORATION warrants to the original purchaser that all products covered under thiswarranty are free from de

Seite 16 - MAINTENANCE

23- ENGD28453NOTES

Seite 17 - GENERATOR

24- ENGD28453QUICK FACTSALWAYS REFER TO THE MANUALS SUPPLIED WITH THIS UNITENGINEGASENGINE OILWATTAGEWIRINGBATTERYVOLT REG.ENGINESTORAGEOPERATIONUse c

Seite 18 - WATTAGE CALCULATIONS

3- ENGD28453indicates an imminently hazardous situation which, if not avoided, will result indeath or serious injury.indicates a potentially hazardous

Seite 19 - Application Guide

4- ENGD28453Operation of unitwhen damaged,or with guards orpanels removed.Removal of guarding couldexpose electrically chargedcomponents and result in

Seite 20 - CAUTION !!

5- ENGD28453RISK OF FIREHAZARDWHAT CAN HAPPENHOW TO PREVENT ITImproper storageof fuelImproperly stored fuel couldlead to accidental ignition. Fuelimpr

Seite 21 - TROUBLESHOOTING GUIDE

6- ENGD28453RISK OF UNSAFE OPERATIONHAZARDWHAT CAN HAPPENHOW TO PREVENT ITOperation ofgenerator incareless mannerAll sources of energy include thepote

Seite 22 - LIMITED WARRANTY

7- ENGD28453RISK OF UNSAFE OPERATION(Continued)HAZARDWHAT CAN HAPPENHOW TO PREVENT ITImproper raising or suspendingcan cause damage to thegenerator.Al

Seite 23

8- ENGD28453HAZARDWHAT CAN HAPPENHOW TO PREVENT ITHAZARDWHAT CAN HAPPENHOW TO PREVENT ITRISK OF MOVING PARTSNever operate generator withguarding or co

Seite 24 - QUICK FACTS

9- ENGD28453NOTE: This manual is a general manual. Information in this manual may ormay not pertain to your model. Please read carefully.NOTE: Left